Home ADI ARTECH Load Cell Mounting Accessories Transducer Customized Sensors Instrumentation Contact
Back
Description
Single Column Rocker type compression Load Cell model-90410 is Strain Gage based which is fully temperature compensated. It is provided with antirotating mechanism and it is self restoring and easy to install. This is also available with mounting module WM-VIII upon request.This is linearised with accuracy of 0.025% of FSD.This Load Cell is provided with surge voltage protection.
Features
 10 to 100 Tf. Capacities offered
 Complete environmental Protection - IP68 class
 Standard output 2.0m V/V available
 Laser welded
 Stain less steel construction

Applications
 Weigh bridge
 Tensile testing
 Industrial automation

Performance Specification
Standard Capacities (Tf.) 10, 20,30,40,50,60,75,100
Excitation Voltage 15 VDC - Maximum 20 VDC
Nominal Output 2.0 mV/V
Non - Linearity < ± 0.025 % FSO (Full Scale Output)
Hysteresis < ± 0.05 % FSO
Non-Repeatability < ± 0.02 % FSO
Creep (30 minutes) < ± 0.03 % FSO
Zero Balance ± 1.0 % FSO
Input Resistance 770 ± 5.0 Ohms
Output Resistance 700 ± 3.0 Ohms
Insulation Resistance (50VDC) > 1000 Mega Ohms at 50 VCD
Cable 4 Core Screen Cable 20 Mtrs.
Safe Overload 150%
Ultimate Overload 300%
Temp. Compensated Range 0-60 0C
Temp. Effect on Output < 0.0015 % FSO/ 0C
Temp. Effect on Zero < 0.0020 % FSO/ 0C
Deflection < 0.4 mm at rated load
Finish & Construction Stainless Steel - 17-4 PH
Outer Casing - SS 304
Environmental Protection Class IP68
Transient Voltage Protection Provided

Electrical Termination
+Input Red
+Output Green
-Input Black
-Output White
  Shield

Type

B

R d D H
10,15,20,30,40 150 150 44 90 75
45,50,60 175 150 44 90 75
75,100 200 300 65 90 100
 View Enlarge Image
 
 View Enlarge Diagram
Download Brochure