Description
Model 60410 is a Strain Gage based low profile bending beam Load Cell and is ideal for precision single point platform scale applications. It is designed for eccentric load sensitivity. Its tool steel Construction is very rugged to withstand shock loads. It is also Provided in Hardnable Stainless Steel - 17-4 PH construction.
Features
 Single Point Capability for Platform Scale.
 Low Profile.
 Minimum Error for Off-Centre loading.
 Supports the Pan size of 750 x 750 (mm).
 100kgf. to 1500 Kgf. Capacities.
 Compact and Light Weight.
 60410-SS is suitable for hygienic applications like food, dairy & pharma
   industries and corrosive applications like chemical industries.

Applications
 Medium Sized Platform Scales.
 Bag Weighing.
 Hopper Weighers.

Performance Specification
Standard Capacities 100, 150, 200, 300,500 , 750, 1000, 1500 - kgf
Excitation Voltage 10 VDC- Maximum 15 VDC
Nominal Output 2.0 m V/ V
Non - Linearity < ±0.025% FSO
Hysteresis < ±0.02% FSO
Non-Repeatability < ±0.01% FSO
Creep (30 minutes) < ±0.03% FSO
Zero Balance ±1.0% FSO
Input Resistance 390 ± 15 Ohms
Output Resistance 350 ± 3 Ohms
Insulation Resistance (50 VDC) > 1000 Mega Ohms
Cable Length (4 Core Screened) 3 mtr. Minimum
Safe Overload of Rated Capacity 150%
Ultimate Overload of Rated Capacity 250%
Temp. Compensated Range 0-60 C
Temperature Effect on Output < 0.0015% FSO/ 0 C
Temperature Effect on Zero < 0.0020% FSO/ 0 C
Eccentric Load Effect < 0.02% of FSO at 1/3 rated load placed within the specified sized platter
Deflection < 0.5 mmat FSO
Tightening Torque 5 m.kg.
Finish & Construction 60410 - Electroless Nickel Plated Tool Steel
60410 - SS - Stainless Steel 17-4 PH
Environmental Protection Class IP65

Electrical Termination
+Input Red
+Output Green
-Input Black
-Output White
  Shield
 View Enlarge Image
 