ADI ARTECH

90210 / 90310

COMPRESSION LOAD CELL

Description

Application

Key Features

Technical Specifications

STANDARD CAPACITY

5,7.5,10,15,20,23,30, 45,50,60,75,100,150,200,300, 500 Tf.

PERFORMANCE

PERFORMANCE

Non- Linearity
Hysteresis
Non-Repeatability
Creep(30minutes)
ZeroBalance
90210 –< ± 0.15%FSO (Full Scale Output) 90310 - < ± 0.025%FSO
< ±0.3% FSO
< ±0.2% FSO
< ±0.3% FSO
±1.0% FSO

ELECTRICAL

ELECTRICAL

Nominal Output
Excitation Voltage
Input Resistance
Output Resistance
Insulation Resistance(50VDC)
Cable Length (4 Core Screened)
10 VDC- Maximum 15 VDC
450 ± 2.0 Ohms
480 ± 3.0 Ohms
>1000 Mega Ohms at 50 VDC
5 Meters
2.0 m V/ V

STRUCTURE

STRUCTURE

Ultimate Overload of Rated Capacity
Safe Overload of Rated Capacity
Allowable Side Load
Deflection
Material of Construction
Environmental Protection Class
300%
150%
50%
< 0.4 mm at FSO
Epoxy Enamel
IP 68

TEMP.

TEMP.

Compensated Temperature
Temperature Effect Output
Temperature Effect Zero
0-60 °C
< 0.0015% FSO/ °C
< 0.0020% FSO/ °C

OPTIONS

OPTIONS

Atex Grade
High Temp.
High Temp. Cable
Extra cable length
Mounting Accessories
Digital Version
Compatible Instrument
II 3D EX tc IIIC T60ºC DC II 3G EX ec IIC GC
Operating Range – 100D°C
Teflon Cable
Specify extra length In Meters
WM-IX
Digital Output
DLC-6M, DLC-6, Summing Junction Box

Application

Industries

Scroll to Top