TENSION LINK LOAD CELL

Capacity
Load Direction

Description

Application

Key Features

Technical Specifications

STANDARD CAPACITY

1, 2, 5, 7.5, 10, 15, 20, 30, 40, 50, 75, 100, 150, 200, 300, 450 TF.

PERFORMANCE

PERFORMANCE

Non- Linearity
Hysteresis
Non-Repeatability
Creep(30minutes)
Zero Balance
<±0.2% FSO (Full Scale Output)
< ±0.2% FSO
< ±0.2% FSO
< ±0.1% FSO
±1.0% FSO

ELECTRICAL

ELECTRICAL

Nominal Output
Excitation Voltage
Input Resistance
Output Resistance
Insulation Resistance(50VDC)
Cable Length
10 VDC- Maximum 15 VDC
775 ± 15 Ohms
700 ± 3 Ohms
> 1000 Mega Ohms(50 VDC)
5 meters
2.0 mV/V

STRUCTURE

STRUCTURE

Safe Overload of Rated Capacity
Ultimate Overload of Rated Capacity
Fatigue Rating
Deflection
Finish & Construction
Environmental Protection Class
150%
300%
106 Full cycles
< 0.5 mm at FSO
Electroless Nickel Plated Tool Steel
Meets IP65

TEMP.

TEMP.

Compensated Temperature
Temperature Effect Output
Temperature Effect Zero
0-60 °C
< 0.0015% FSO/°C
< 0.0020% FSO/ °C

OPTIONS

OPTIONS

High Temp.
High Temp. Cable
Compatible Instrument
Wireless Telemetry
Operating Range – 100D°C
Teflon Cable
DLC-6M, DLC-6
With remote Display