70210
Double Ended Shear Beam Load Cell - Center Loaded End Supported
Capacity
- 0-2.5 Tf to 0-100 Tf
Load Direction
- Compression only
Description
-
70210 is double ended shear beam load cell which is ideally suited for truck, track, tank & hopper weighing applications. It is designed to withstand the rigorous of harsh environmental conditions. It is constructed from Tool Steel. Can also be offered with complete mounting assembly – WM-II.
It is also available in Digital version, equipped with fully Embedded Electronics with RS 485 Communication capability for easy interface over long distance without signal loss.
Application
- Silo Weighing
- Onboard Weighing
- Weigh Bridge Scale
- Large Platform Scales
- Truck, Tank & Hopper weighing
Key Features
- End mounted and center loaded design provides better stability and accuracy.
- It is temperature compensated for 10 - 50 Deg. C.
- High accuracy available As per standard ISO 376:2011
- Triple Sealing for environmental Protection
- Complete Environmental Protection – Meets IP 65, IP 67 & or IP 68 class
- Electro less nickel-plated tool steel & stainless steel constructions
- A high-temperature version can be provided on request
- Wide range of capacities from 2.5 TF to 100 TF
- Standardized output (2.0 mV/V) and customized output can be provided on request
- Calibration in mV/V/Ω
- Can be customized to suit customer’s need
Technical Specifications
STANDARD CAPACITY
2.5, 5, 7.5, 10, 15, 20, 25, 30, 40, 50, 65, 75, 100, 125 -TF
PERFORMANCE
PERFORMANCE
Non- Linearity
Hysteresis
Non-Repeatability
Creep(30minutes)
ZeroBalance
<±0.05% FSO (Full Scale Output)
<±0.03% FSO
<±0.02% FSO
< ±0.03%FSO
± 1.5 % FSO
ELECTRICAL
ELECTRICAL
Output
Excitation Voltage
Input Resistance
Output Resistance
Insulation Resistance
Maximum 15 VDC (Suggested 5VDc / 10VDc)
770 ± 20.0 Ohms
700 ± 2 Ohms
(100 VDC) > 1000 Mega Ω (Ohms)
3.00 mV/V (Customized Output ailable on request)
STRUCTURE
STRUCTURE
Safe Overload
Of Rated Capacity
Ultimate Overload
of Rated Capacity
Allowable Side Load
Deflection
Finish Product
As per IS/IEC 60529:2001
150%
200%
50%
< 0.5 mm at FSO
Electro less nickel-plated tool steel / SS 17-4 PH
IP68
TEMP.
TEMP.
Operating
Temperature
Compensated
Temperature
Temperature
Effect Output
Temperature
Effect Zero
0ºC to 60ºC (Optional 90ºC, 120ºC, 150ºC)
10ºC to 50ºC (Optional 90ºC, 120ºC, 150ºC)
< 0.0015%FSO/ ºC
< 0.0020%FSO/ ºC
OPTIONS
OPTIONS
Atex
High Temperature Range
High Temp. Cable
Extra cable length
Mounting Accessories
Digital Version
Accessories
II 3D EX tc IIIC T60ºC DC , II 3G EX ec IIC GC
40ºC to 90ºC (Temperature Effect on Output & Zero : < 0.020% FSO/ ºC)
Teflon Cable
Specify extra length In Meters
WM-II
Digital Output
DLC-6 | DLC-6M | HH-06 DIGITAL LOAD CONTROLLER (MULTI. O/P)