ADI ARTECH

60810

Single Point Platform Load Cell

Description

Application

Key Features

Technical Specifications

STANDARD CAPACITY

500, 750, 1000, 1500, 2000, 3000 Kgf

PERFORMANCE

PERFORMANCE

Non- Linearity
Hysteresis
Non-Repeatability
Creep(30minutes)
ZeroBalance
< ±0.025% FSO (Full Scale Output)
< ±0.02%FSO
< ±0.01%FSO
< ±0.03%FSO
±1.0%FSO

ELECTRICAL

ELECTRICAL

Nominal Output

Excitation Voltage
InputResistance
OutputResistance

InsulationResistance

10 VDC- Maximum 15 VDC
390 ± 15 Ohms
350 ± 3 Ohms
> 1000 Mega Ohms at 50 VDC
2.0 m V/V

STRUCTURE

STRUCTURE

Safe Overload Of Rated Capacity
Ultimate Overload of Rated Capacity
Allowable Side Load

Deflection

Platter Size

Finish Product

Tightening Torque

As per IS/IEC 60529:2001

150%
250%
50%

< 0.4 mm at FSO

1000 mm X 1000 mm

Electro less Nickel Plated Tool Steel

7.5 m. kg.

IP 67

TEMP.

TEMP.

Compensated Temperature
Temperature Effect Output

Temperature Effect Zero

Eccentric Load Effect

0ºC to 60ºC
< 0.0015% FSO/ ºC

< 0.0020% FSO/ ºC

< 0.02% of FSO at 1/3 rated load placed within 500mm radius from center of load cell

OPTIONS

OPTIONS

Extra cable length
Digital Version
Compatible Instrument
Specify extra length In Meters
Digital Output
DLC-6M, DLC-6, Summing Junction Box

Industries