70510
Pin Type Load Cell
Capacity
- 0 - 0.5 to 0 - 400 Tf.
Load Direction
- Tension & Compression – Universal
Description
-
70510 Pin Load Cell is CE Certified strain gage based and is used where pins or large bolts would generally be carrying the load. Typically this will include shackle pin, clevis pins & pulley shafts. This is constructed from heat treated stainless steel, suitable for food industries & harsh corrosive environment. Load pin is Double Ended Shear Beam Type load cell which is provided with slot for keeper plate for load directions, anti-rotations & retaining purposes.
Digital Version is also offered, equipped with Fully Embedded electronics with RS485 communication capability for easy interface over long distance without signal loss.
Application
- Elevator, Hoist & Crane Load monitor
- Tow bar Connection
- Rope/Cable tension measurement by inserting as D-Shackle pin
- Front end Loader
- Rail road coupling
- Process & Automation
Key Features
- CE Rated Available in capacities of 0 - 0.5 to 0 - 400 Tf.
- Meets complete environment protection IP 65 class.
- Standard 1 mv/v output sensitivity is available.
Technical Specifications
STANDARD CAPACITY - (Tf.)
0.5,1,2,3,5,10,20,30,50,,75,100,150,
200,300,400
PERFORMANCE
PERFORMANCE
Non- Linearity
Hysteresis
Non-Repeatability
Creep(30minutes)
ZeroBalance
< ±0.5% FSO (Full Scale Output)
< ±0.3% FSO
< ±0.2% FSO
< ±0.01% FSO
±1.0% FSO
ELECTRICAL
ELECTRICAL
Nominal Output
Excitation Voltage
Input Resistance
Output Resistance
Insulation Resistance(50VDC)
Cable Length (4 Core Screened)
10 VDC- Maximum 15 VDC
390 +/-5 / 770 +/- 20 Ohms
350 +/- 2 / 700+/- 5 Ohms
≥1000 Meg Ohms
1 meters
IMV/V
STRUCTURE
STRUCTURE
Safe Overload of Rated Capacity
Ultimate Overload of Rated Capacity
Deflection
Finish & Construction
Environmental Protection Class
150%
250%
< 0.4 mm at FSO
Stainless Steel 17-4 ph Sensing element
IP 65
TEMP.
TEMP.
Compensated
Temperature
Temperature
Effect Output
Temperature
Effect Zero
0-60 °C
< 0.005% FSO/ °C
< 0.005% FSO/ °C
OPTIONS
OPTIONS
Atex Grade
High Temp.
High Temp. Cable
Extra cable length
Mounting Accessories
Dual Bridge
Digital Version
Compatible Instrument
Wireless Telemetry
II 3D EX tc IIIC T60ºC DC II 3G EX ec IIC GC
Operating Range – 100D°C
Teflon Cable
Specify extra length In Meters
WM-IX
Redundancy for uninterrupted measurement in critical applications
Digital Output
DLC-6M, DLC-6, Jumbo Display
With remote Display