ADI ARTECH

90610-T

Low Profile Pancake Load Cell - Center Loaded

Capacity
Load Direction

Description

Application

Key Features

Technical Specifications

STANDARD CAPACITY

0.05,0.1,0.2,0.5,1.0,1.5,2,2.5,3,5,7.5,10,15,20, 30 ,50,75,100,150,200,300,450,500   -Tf.

PERFORMANCE

PERFORMANCE

Non- Linearity
Hysteresis
Non-Repeatability
Creep(30minutes)
ZeroBalance
< ±0.1% FSO (Full Scale Output)
< ±0.15% FSO
< ±0.1% FSO
< ±0.04% FSO
±1.0% FSO

ELECTRICAL

ELECTRICAL

Output
Excitation Voltage
Input Resistance
Output Resistance
Insulation Resistance
10VDC-Maximum15VDC
770 ± 20 Ohms 2T & Above 390 ± 10 Ohms up to 1T
700 ± 7 Ohms 2T & Above 350 ± 5 Ohms up to 1T
> 1000 Mega Ohms
3.00 mV/V±0. 05%:20210 (Customized Output ailable on request)

STRUCTURE

STRUCTURE

Safe Overload Of Rated Capacity
Ultimate Overload of Rated Capacity
Allowable Side Load
Deflection
Finish Product
IP Rating
150%
250%
50%
< 0.4mmatFSO
Electrolessnickel-platedtoolsteel
IP65

TEMP.

TEMP.

Operating Temperature
Compensated Temperature
Temperature Effect Output
Temperature Effect Zero
0ºC to 60ºC
10ºC to 50ºC
< 0.005% FSO/ °C
< 0.005% FSO/ °C

OPTIONS

OPTIONS

Mounting Accessories
Dual Bridge
Digital Version
Compatible Instrument
WM-XI
Redundancy for uninterrupted measurement in critical applications
Digital Output
DLC-6M, DLC-6, Summing Junction Box

Industries

Scroll to Top