STANDARD CAPACITY

2.5, 5, 7.5, 10, 15, 20, 25, 30, 40, 50, 65, 75, 100, 125 -TF

PERFORMANCE

PERFORMANCE

Non- Linearity
Hysteresis
Non-Repeatability
Creep(30minutes)
ZeroBalance

<±0.05% FSO (Full Scale Output)

<±0.03% FSO

<±0.02% FSO
< ±0.03%FSO
± 1.5 % FSO

ELECTRICAL

ELECTRICAL

Output
Excitation Voltage
Input Resistance
Output Resistance
Insulation Resistance

Maximum 15 VDC (Suggested 5VDc / 10VDc)

770 ± 20.0 Ohms
700 ± 2 Ohms

(100 VDC) > 1000 Mega Ω (Ohms)

3.00 mV/V (Customized Output ailable on request)

STRUCTURE

STRUCTURE

Safe Overload Of Rated Capacity
Ultimate Overload of Rated Capacity
Allowable Side Load
Deflection
Finish Product

As per IS/IEC 60529:2001

150%

200%

50%
< 0.5 mm at FSO

Electro less nickel-plated tool steel / SS 17-4 PH

IP68

TEMP.

TEMP.

Operating Temperature
Compensated Temperature
Temperature Effect Output
Temperature Effect Zero

0ºC to 60ºC (Optional 90ºC, 120ºC, 150ºC)

10ºC to 50ºC (Optional 90ºC, 120ºC, 150ºC)

< 0.0015%FSO/ ºC
< 0.0020%FSO/ ºC

OPTIONS

OPTIONS

Atex

High Temperature Range

High Temp. Cable
Extra cable length
Mounting Accessories
Digital Version

Accessories

II 3D EX tc IIIC T60ºC DC , II 3G EX ec IIC GC

40ºC to 90ºC (Temperature Effect on Output & Zero : < 0.020% FSO/ ºC)

Teflon Cable